However, it's not just an electrical problem. The entire system needs to work together to dissipate heat. This includes ensuring that mechanical and design requirements, such as size and weight, are also met.
Passive cooling

There are two main approaches to dealing with the heat generated in an electronic system: passive cooling and active cooling. Passive cooling relies solely on physics: the generated heat dissipates into the environment.
The documentation for your chosen power supply will provide guidance on the operating temperature range, mounting, and cooling requirements. A good example is the Traco Power TBLC 90 series 90-watt DIN rail-mounted unit that utilizes convection cooling. This unit is specified [LINK: https://www.tracopower.com/sites/default/files/products/datasheets/tblc90_datasheet.pdf] to operate between -20°C and +70°C. However, above +55°C, the power supply should reduce the load by 2.5%/°K.
A natural convection rate of 20 linear feet per minute (LFM) is specified around the unit. Regarding the installation manual [LINK: https://www.tracopower.com/sites/default/files/products/installation_instructions/tblc90_installation.pdf], the mounting orientation is also defined and indicates that the air circulation should be from bottom to top (image 1).

Image 1: The DIN rail mounted power supply relies on convection cooling.
The Mathematics of Heat Dissipation:
Power supply components, such as MOSFET transistors, have fairly robust metal tabs integrated into the casing (Figure 2). With the silicon die mounted on this casing, heat is dissipated through the material. However, there are limits to the amount of excess heat the casing can handle on its own.
To determine this limit, you should check the datasheet and look up the junction thermal resistance to ambient (RθJA). This defines the expected temperature rise in degrees Celsius for each watt of power dissipated by the silicon die.

Image 2: Power devices have a metal tab (left, center) or pad (right) to dissipate heat.
You must also consider the ambient temperature of the environment in which your application operates. Even in an office or home, a power supply can be exposed to direct sunlight at certain times of day, raising the ambient temperature to over 30°C. Such an increase can push the unit's semiconductor devices beyond their specified temperature limit.
If your maximum temperature limit is 150°C (TJmax) and the ambient temperature is 30°C (TA), you only have a temperature increase of 120°C available. If the RθJA is 23.9°C/W, you will only be able to dissipate about 5 W (PD) without using a heatsink, as indicated by (TJmax – TA) ÷ RθJA.
In any case, the metal tab or pad on the power supply is not designed to be the ultimate heat dissipation solution. It is the method by which the semiconductor device can dissipate heat over a larger thermal mass. This could be a heat sink or the casing, but it could also be a metal embedded in the printed circuit board.
Cooling to the Copper of Your Printed Circuit Board:
In some applications, the copper of the printed circuit board can be used. This assumes there is sufficient space to create a surface large enough for this purpose. To ensure good thermal bonding, the tab or pad is soldered to the printed circuit board.
Another method involves using a printed circuit board bonded to a piece of aluminum or copper. LED lamps are a good example of an application that relies on printed circuit boards bonded to aluminum.
If the budget allows and the design requires it, it is also possible to have a copper block, known as a copper coin, embedded in the printed circuit board. This allows heat-dissipating components to be thermally bonded to it (Figure 3). This method can be helpful when the application is sealed and ventilation grilles are not feasible.

Image 3: Use of a copper coin embedded in the printed circuit board to dissipate heat.
How to Add a Heatsink:
Heatsinks and printed circuit boards use aluminum or copper and balance total mass with surface area to provide the desired heat dissipation. Such devices typically have numerous fins or protrusions to achieve this.
Both materials have good thermal properties (237 W/m K for Al and 401 W/m K for Cu). The raw material cost of aluminum is three and a half times lower than that of copper.
To ensure a good thermal bond, a thermal pad or paste is applied to the power supply flange and secured with a screw, providing mechanical fixation.
To calculate the total thermal resistance when using a heatsink, you need the thermal resistance of the junction to the case (RθJC) of the semiconductor device along with the thermal resistance of the heatsink and the thermal paste. Assuming the semiconductor's RθJC is 1.7 °C/W, the heatsink's is 2.67 °C/W, and the thermal paste's is 0.33 °C/W, the total thermal resistance (RTOTAL) is 1.7 + 2.67 + 0.33 = 4.7 °C/W. The operating temperature of this assembly is then calculated using (PD × RTOTAL) + TA.
Therefore, when 5 W is dissipated as above at TA of 30 °C, we can expect the temperature to rise to (5 × 4.7) + 30 = 53.5 °C.
Active Cooling:
There are cases where a heatsink is insufficient. This can occur under all operating conditions or only at the extremes of operation. To address this, we have the option of active cooling, which translates into integrating a fan.
This makes sense, but it also becomes a potential point of failure. When the converter relies on forced air to keep the unit within the specified temperature range, you must ensure that the fan spins when activated, and you may even want to continuously monitor the fan speed. Fortunately, many semiconductor vendors offer fan controllers, such as the EMC2301 from Microchip Technology [LINK: https://www.microchip.com/en-us/product/emc2301]. These I2C/SMBus devices are easy to integrate with microcontrollers, often include closed-loop control, and allow for continuous fan monitoring.
Alternatively, liquid cooling is an option. This is common in electric vehicles, where IGBTs, MOSFETs, and power modules are integrated into motor inverters and high power density power converters.
Summary:
The importance of thermal design is increasing as applications demand ever smaller, more compact, and higher-power-density power supplies. However, methods for addressing this challenge depend on available budget and design constraints. The preferred and lowest-cost approach is passive cooling through natural convection and a heatsink. Active cooling, such as forced airflow via a fan, is the next step, but it requires fan monitoring. If the fan fails, the power supply will quickly overheat and become inoperable. To address thermal challenges, always read the datasheet and installation manual carefully, and if anything is unclear, rely on suppliers like Traco Power, who are always ready to provide technical support.
Author:
Article provided by Traco Electronic AG – http://www.tracopower.com