The AEA800F series is suitable for body-floating (BF) applications and meets 2MOPP (IN/OUT) and 1MOPP (OUT/FG) safety requirements. Its design is optimized for air convection, making it ideal for use in equipment operating in low-noise environments.
The AEA800F is capable of delivering 300% of its rated power, cooled by air convection, for up to 3,000 milliseconds, meeting the latest market requirements for industrial and medical equipment.
The AEA800F is certified to EN62477-1 Overvoltage Category Three (OVC III), meaning that end equipment powered by this product can be connected directly to the main distribution panel without additional insulation.
For medical applications, the AEA800F's input-to-output isolation meets 2 MOPP, its input-to-ground 1 MOPP, and its output-to-ground 1 MOPP, making the product suitable for body-floating (BF) applications. The units are approved in accordance with ANSI/AAMI ES60601-1 and EN60601-1 3rd edition.
The AEA800F has an input-to-output isolation of 4,000 VAC, an input-to-ground (FG) isolation of 2,000 VAC, and an output-to-ground (FG) isolation of 1,500 VAC.
Designed for international applications, the versatile AEA800F has an input voltage of 85 to 264 VAC. It features three output voltages: 24V, 36V, and 48V, with corresponding current ratings of 34A (72.5A peak), 22.7A (48.4A peak), and 17A (36.3A peak). The output voltage can be adjusted using a built-in potentiometer.
To achieve low harmonic distortion, the AEA800F utilizes an active power factor correction (PFC), and the switching stage employs a resonant LLC topology using the latest generation of power semiconductors, resulting in a typical efficiency of up to 95%.
For additional power, up to six AEA800F units can be connected in parallel. When connected in parallel, adjusting the output voltage on the master unit automatically adjusts the output voltage of the slave units to match.
Optimized for convection cooling, the AEA800F can operate in an ambient temperature range of -20 to +70 degrees Celsius. Depending on the mounting method and ventilation used in the final equipment, a power reduction may apply as specified in the technical documentation.
The AEA800F includes inrush current, overcurrent, and overvoltage protection circuits, as well as thermal protection.
In its open rack configuration, the AEA800F measures 50 x 127 x 203.2 mm (1.97 x 5 x 8 inches) and weighs a maximum of 1.4 kg with the cover included.
The AEA800F meets the following safety requirements: UL (USA), C-UL (Canada), DEMKO (Denmark), and TUV (Germany). The product is certified to UL62368-1, EN62368-1, and EN62477-1 (OVC III).
To meet specific application requirements, a range of options are available, including: Cover (C), Additional Cover (N), Vertically Positioned Screws on Terminal Block (T), Terminal Block Replaced by a Connector (J), Extended Features: Auxiliary Outputs (AUX1 12V1A), (AUX2 5V1A), Remote On/Off and Alarm (R3), UL508 Certification (T5), Overcurrent Protection Mode Changed from Hiccup to Off (P5).
The AEA series is suitable for a wide range of applications such as: robots and robotics, infusion pumps, ventilators, actuators, process control, radio and transmission equipment, and emergency signaling.
The AEA800F series has a full five-year warranty and complies with European RoHS, REACH, and Low Voltage Directives.
The AEA series includes three models ranging from 600 to 1000 W, the AEA600F, the AEA800F and the AEA1000F, all of which offer maximum power for demanding applications.