This manual was written by:
- Carlos J. Vives, CEO; David de Paco, Smart City Solutions and Jordi Vila, Product Manager – Smart City Solutions, of AFEI Sistemas y Automatización, SA (AFEISA)
- Robert Merchante, Senior Product Manager Outdoor Lighting, of Simon Lighting SA
- Alberto García, Chief Marketing Officer and José Ignacio, Project Manager, of Sinapse Energia.
- Juan Carlos Lopez, Business Development Manager, of Applus Laboratories
- David Rius, Technical Sales and Joan Presas, Executive Manager Director, of Vossloh-Schwabe Ibérica SL
The manual was reviewed by:
- Susana Prieto, Cluster Manager; Sergi Gómez, Project Manager and Leticia Gómez, Project Manager, of the Smart Technologies for Cities, Buildings and Industry Cluster DOMOTYS
- Jessica Juliette Kamps, Cluster Manager, of the CICAT Lighting Cluster
Index
1. General Information 5 1.1. Introduction 5 1.2. Objective of the document 5 1.3. Scope of the document 6 1.4. Target audience of the document 6
2. Glossary 7
3. Technologies 10 3.1. Level 1: Lighting with drive system 10 3.1.1. Control Centers 10
3.1.1.1. Photocell 11 3.1.1.2. Astronomical clock 12 3.1.1.2.1. Reprogrammable astronomical clock 13 3.1.1.3. Remote control equipment 13 3.1.2. Light points (Drivers) 14 3.2. Level 2: Lighting with energy saving systems 14 3.2.1. Lighting with flow stabilizing regulators 15 3.2.1.1. Remote management equipment 15 3.2.2. Lighting with energy-saving system by light points 16 3.2.2.1. Regulation protocols 17 3.2.2.2. Remote management equipment for light points 19 3.3. Grade 3: Remote management system 19 3.3.1. Remote management system of control centers 19 3.3.1.1. Communication with control centers 21
3.3.1.2. Remote management platforms of control centers 22 3.3.1.3. Main functions of a remote management system 23 3.3.1.4. Other functions and remote management systems 24
3.3.2. Bidirectional remote management of light points 25 3.3.2.1. Remote management of light points by PLC 25 3.3.2.2. Remote management of light points by RF 26
3.3.2.2.1. Integration in luminaires 27
3.3.2.2.2. Wireless Technologies 28 3.3.2.3. IoT Light Point Remote Management 30 3.3.3. Other functionalities of light point remote management 30 3.3.3.1. Geolocation 30
3.3.3.2. Sensorization 31 3.3.4. Light point remote management system 31
4. Adaptation of technologies according to the needs to be met 33 4.1. Grade 1: Lighting with drive system 33 4.2. Grade 2: Lighting with energy saving systems 34 4.3. Grade 3.1: Remote management systems 35 4.4. Grade 3.2: Bidirectional light point remote management 36
5. Regulations and certifications 41 5.1. Regulations and operation of the installation 42 5.1.1. Low Voltage Electronic Regulations 42 5.1.2. Energy Efficiency Regulations for Outdoor Lighting 43 5.2. Product regulations 44 5.2.1. Luminaire 44 5.2.1.1. Electrical safety 44 5.2.1.2. Electromagnetic compatibility 44 45
5.2.1.3. Human exposure
5.2.1.4. Optical tests and photobiological safety 45
5.2.1.5. Functional requirements and performance 45 5.2.2. Drivers/power supplies 45 5.2.2.1. Electrical safety 45 5.2.2.2. Functional requirements 45 5.2.3. Communication modules / Remote management equipment 46 5.2.3.1. Electrical safety 46 5.2.3.2. Electromagnetic compatibility 46 5.2.3.3. Radio 46 5.2.3.4. Human exposure 47 5.2.4. LED module 47 5.2.4.1. Electrical safety 47 5.2.4.2. Functional requirements/performance 47 5.2.5. Columns and poles 47 5.2.6. Electrical cabinets 48 5.2.6.1. Electrical safety 48 5.2.6.2. Electromagnetic compatibility 48 5.2.7. Combined systems 48
6. Points to consider when drafting tender documents 49 6.1. Interoperability 49 6.2. Training 50 6.3. Maintenance of remote management equipment and systems 50
7. Bibliography
6.3.1. SaaS (Software as a Service)
General Information 1.1. INTRODUCTION
The development of lighting control and information transmission technologies has led to the emergence of numerous control and regulation systems for managing both public and private outdoor lighting.
These innovations can bring significant benefits, resulting in more energy-efficient lighting installations, reduced maintenance costs, and improved control over luminaires by the manager or owner of the installation. They also contribute to better service for citizens, leading to an improved quality of life and greater safety. However,
the proliferation of multiple control and regulation systems, based on different control concepts, communication technologies, and functionalities, often leaves technicians responsible for drafting outdoor lighting projects that require a control and regulation system unsure of the optimal solution for their project. Furthermore, in many cases, there is a genuine lack of understanding regarding the technical possibilities, advantages, and disadvantages offered by each technology. This leads to the specification of a very generic system in the tender
This document is intended to help technicians and other stakeholders become familiar with the basic technologies available on the market, understand the advantages and disadvantages of each system, learn about the applicable regulations, and thus choose the appropriate system for the project based on the needs and requirements of these control and regulation systems.
1.2. OBJECTIVE OF THE DOCUMENT
The objective of this document is to establish the minimum knowledge framework necessary to assist technicians in tendering, selecting, and implementing a control and regulation system for an outdoor lighting installation. To achieve this objective, the document will focus on developing the following points:
1. Defining the various control and regulation technologies available on the market, suitable for application to outdoor lighting control, as well as their fundamental characteristics, capabilities, and performance.
2. Helping to determine the best system based on the needs to be met.
3. Drafting the tender document clearly and concisely, adequately specifying the chosen solution, the functions the system must perform, the services
the supplier must provide, and the associated maintenance.
4. Understanding the regulations applicable to this technology and the requirements that must be met by suppliers and the equipment they install to guarantee product quality and proper
operation.
1.3. SCOPE OF THE DOCUMENT
This document covers all outdoor lighting applications, regardless of the size or type of installation, both public and private, that will be equipped with a control and regulation system; or those installations where the implementation of a control and regulation system is planned for the future and/or where the installation components are intended to be prepared for the easy implementation of additional equipment.
1.4. TARGET AUDIENCE
This document is intended for technicians responsible for carrying out outdoor lighting installation projects, both public and private, that include a control and regulation system. This group of professionals includes the following:
• Municipal engineers from the technical services departments of city councils.
• Engineers from the technical services departments of provincial councils that serve the towns within their
provincial jurisdiction.
• Private engineers/engineering firms contracted to carry out outdoor lighting projects
for towns, housing developments, roads, etc.
• Maintenance companies and energy service companies.
• City councils.
• Installers.
• Any other person involved in the public lighting sector.
Glossary
(Application Programming Interface): An API represents the communication capabilities between software components. It consists of a set of calls to certain libraries that provide access to specific services from within processes and represents a method for achieving abstraction in programming, generally (though not necessarily) between the lower and upper layers of the software.
Bluetooth: is an industry specification for wireless personal area networks that enables the transmission of voice and data between different devices using a radio frequency link in the 2.4 GHz ISM band.
Control Center: an electrical panel equipped with actuation and protection devices, as well as control systems, that provides electrical power to public lighting installations. It may contain the metering equipment of the supplying company.
Bidirectional Communication: an environment between two or more elements in which all can send and receive messages.
Unidirectional Communication: an environment between two or more elements in which one sends messages and the rest only receive them.
DALI (Digital Addressable Lighting Interface): This is a dedicated protocol for digital lighting control that allows for the easy installation of robust, scalable, and flexible lighting networks. In the case of remote management, it is used as the communication protocol for the commands sent from the remote management module to the driver.
Driver: This is the auxiliary power supply device for the LED module, which regulates and controls the output current required by the LED for its proper operation and to deliver the power intended for that light point.
Remote management equipment: This is a set of components designed for the remote control of a lighting installation. Control includes performing various actions, such as activation, data reading, and generating technical alarms.
Remote control equipment: These are astronomical clocks with communication capabilities that allow for sending remote control commands to turn the installation on or off, reprogram specific schedules, and record key events related to the installation's on/off operation.
Photocell: A photoelectric sensor that responds to changes in ambient light intensity, activating or deactivating a relay or contact based on the received light intensity values.
GPS: A global positioning system that allows the position of any object on Earth to be determined with centimeter accuracy.
IoT (Internet of Things): A concept referring to the digital interconnection of everyday objects via the internet.
LED (Light Emitting Diode): A light source made of a semiconductor material with two terminals. It is a pn junction diode that emits light when activated. If a suitable voltage is applied to the terminals, electrons recombine with holes in the pn junction region of the device, releasing energy in the form of photons. This effect is called electroluminescence, and the color of the generated light (which depends on the energy of the emitted photons) is determined by the band gap of the semiconductor. This technology has become widely used in modern lighting.
LoRaWAN: This is a specification for low-power, wide-area networks, specifically designed for low-power devices operating in local, regional, national, or global networks.
NEMA (National Electrical Manufacturers Association): This is a US industry association responsible for numerous common industry standards used in the electrical field. Among others, it has established a wide range of standards for electrical equipment enclosures, as well as for connecting photocells or communication nodes to luminaires. Remote Management Platform: This is software for controlling and managing data from remote management equipment. This platform can be hosted in a local control center or on a web server.
PLC (Power Line Communications): This refers to various technologies that use conventional electrical power transmission lines to transmit signals for communication purposes. Broadband PLC technology leverages the electrical grid to create a high-speed digital data transmission line, enabling, among other things, internet access.
Light point: A complete luminaire that is typically connected to and powered by a control center.
Flux regulator/stabilizer: A device that allows for adjustment of the lighting level by varying the voltage of the power supply line.
Astronomical clock: A time switch that automatically determines sunrise and sunset times, enabling the activation or deactivation of a relay or contact based on these times.
SigFox: A low-power, wide-area global network operator that enables IoT connectivity.
Lux probe: A photoelectric sensor that responds to changes in ambient light intensity, varying the analog or numerical value of its output according to the received light intensity values in lux.
WiFi: A mechanism that allows wireless internet access for various devices by connecting them to a specific network.
Zhaga: An international organization that establishes industry specifications for interfaces for components used in LED luminaires. Among other things, it has established a system for connecting communication nodes to luminaires.
Zigbee: This is the name of a specification for a set of high-level wireless communication protocols for use with low-power digital broadcasting, based on the IEEE 802.15.4 standard for wireless personal area networks (WPANs). It is designed for applications requiring secure communication with low data transmission rates and maximized battery life.
1-10V: This is a regulation system based on a 1V to 10V analog signal that modulates the luminous flux between 10% and 100%. In remote management applications, it is used as the communication system for commands sent to the driver. 6LowPAN
(IPv6 over Low Power Wireless Personal Area Networks): This is an open standard defined by the IETF (Internet Engineering Task Force) that enables the use of IPv6 over networks based on the IEEE 802.15.4 standard, allowing devices to communicate directly with other IP devices.
Technologies:
The level of application of the smart city concept to street lighting is defined in three levels of functionality (hereinafter, levels) with their corresponding sublevels.
These allow for the progressive implementation of measures aimed at intelligent street lighting management, achieving greater energy savings and improved service for citizens.
Different levels can be applied to the same municipality depending on the needs of each type of installation and the available resources. Each level is valid and they are complementary; therefore, a study and implementation plan for the different levels must be carried out beforehand.
3.1. LEVEL 1: LIGHTING WITH AN OPERATING SYSTEM
The operating system ensures that the outdoor lighting installation switches on and off automatically during a period between sunset and sunrise. Its objective is to avoid consumption outside of necessary hours and save energy, in accordance with the conditions detailed in Article 8 of Royal Decree 1890/2008 on the Energy Efficiency Regulations for Outdoor Lighting Installations (hereinafter REEA).
Specific requirements apply to certain types of lighting, such as ornamental or sports facility lighting, which must have the ability to program operating cycles: daily, weekly, monthly, or annually, as well as for tourist seasons, local festivals, or events.
It is important to note that the operating system must always guarantee the activation of the installation for road safety and public order reasons and, furthermore, be as efficient as possible, switching off at the appropriate time and avoiding unnecessary or premature activations.
3.1.1. Control Centers.
Level 1 is valid for any type of lighting, since it only involves switching the entire power supply of the electrical panel on and off for the entire outdoor lighting installation (hereinafter, the Control Center), typically using a main contactor.
The Control Center corresponds to the protection, measurement, and control panel, as defined in ITC-BT-09 of Royal Decree 842/2002 on the Low Voltage Electrotechnical Regulations (hereinafter, the REBT), where the corresponding operating system and the general electrical protections for each of the power supply outputs of the associated lighting points are located.
The Control Center also typically includes the main protection box and the metering equipment of the supplying company.
3.1.1.1. Photocell.
This is a photoelectric sensor that responds to changes in ambient light intensity, activating or deactivating a relay or contact based on the light intensity values received.
Its main advantage is its ability to adapt to unexpected changes in ambient light intensity caused by weather or other phenomena.
Its main disadvantage is that it operates based on the light intensity received by the sensor, which can be affected by obstructions or interference with the sensor reading, as well as by pollution, rain, or other elements that, over time, cover or affect the sensor's surface. This means it may activate lighting during daylight hours, generating unwanted energy consumption, or fail to function correctly at sunrise and sunset.
Consequently, it may not be an energy-efficient solution and may require more maintenance, as regular cleaning is necessary to ensure proper operation.
According to the energy efficiency regulation (REEA), it is not a valid solution in outdoor lighting installations with a power rating of more than 5 kW.
3.1.1.2. Astronomical Clock.
An astronomical clock is a time switch with an automatic method for determining sunrise and sunset times, enabling it to activate or deactivate a relay or contact based on these times.
The performance of an astronomical clock depends on the method used to determine the daily sunrise and sunset times, which is determined by the installation's location.
The daily calculation method using an astronomical algorithm is more precise than methods based on tables and geographical zones. Furthermore, for daily operations, it is advisable that the astronomical calculation be highly accurate, ideally using the location's geographical coordinates in degrees and minutes.
It should also allow for adjusting the lighting's switching on and off times, correcting operating hours based on sunrise and sunset times in x minutes, and/or the time in hours and minutes, thereby achieving greater energy efficiency.
Another key element is the potential for the internal clock of the equipment to drift due to temperature changes and the passage of time, which may require periodic resetting.
Some astronomical clocks have an internal GPS system that, in addition to automatically locating the precise position of the installation, allows for automatic and constant time synchronization, increasing accuracy and eliminating the need for maintenance.
Furthermore, to avoid resetting the clock every six months, it should have an automatic time change function for winter and summer time.
As indicated in the REEA (Spanish Astronomical Equipment Regulations), it should also allow for customized scheduling for special days and/or holidays, such as vacation periods and other special events, enabling the creation of specific calendars for each installation or type of installation.
In addition, it should have various outputs to activate other elements such as street lighting, ornamental fountains, energy-saving systems, billboards, shop windows, garden irrigation, road signs, monuments, facades of landmark buildings, pedestrian area access points, etc.
The inclusion of a display and keypad makes it easy to monitor the clock's status and operations, as well as configure it locally or activate different circuits for maintenance.
It must be DIN rail mountable to ensure compatibility with most electrical control center standards.
The REEA (Spanish Electrical Installation Regulation) requires this type of solution for installations exceeding 5 kW.
3.1.1.2.1. Reprogrammable Astronomical Clock
Most astronomical clocks allow you to set the time, change the programming, and in some cases even modify the specific operating schedules.
This is usually done using the device's own keypad, but some models allow for easy and simple reprogramming via remote control, Bluetooth technology, or a memory storage device, though this still requires a trip to the control center.
3.1.1.3. Remote Control Equipment.
Remote control equipment consists of astronomical clocks with communication capabilities that allow for the transmission of remote control commands to switch the installation on or off at a specific time, as well as the reprogramming of specific schedules. This equipment typically records the main events related to the installation's switching on and off.
Remote control equipment may also incorporate alarm inputs, so that it detects and records alarms generated in the installation based on changes in the operating state of residual current devices (RCDs), contactors, manual switches, door controls, and other devices.
All this data can be accessed and downloaded locally or remotely via a wired or wireless connection to the equipment.
Furthermore, this communication capability must allow for the transmission of remote control commands to switch the installations on or off at a specific time, as well as the reprogramming of specific schedules.
The programming template function, based on the type of lighting, is crucial. This allows a group of control centers to be assigned to a specific template and enables the automatic transmission of new programming to all assigned control centers.
The control and remote control units must be autonomous, meaning that even in the event of a loss of communication with the system, they will still execute their programmed switching on and off sequences.
For the correct operation of the programmed maneuvers in the calendar of the different control centers, the remote control equipment's clock must be highly accurate and update its time periodically, for example, through automatic synchronization of its internal clock via internet time servers.
3.1.2. Light Points (Drivers)
Although the control system is centralized, via the activation or deactivation of the main power supply to the light points, the new functions provided by LED drivers must be considered.
The driver is the auxiliary power supply device for the LED module, regulating and controlling the output current required by the LED for its proper operation and to deliver the power intended for that light point. The total power of each light point is obtained by taking into account the driver's nominal power and the LED module's power consumption.
LED luminaire drivers must be equipped with a system capable of managing the emitted luminous flux. This is achieved through autonomous operation that begins when the power supply is activated from the control center and ends when the power supply is disconnected. During this period, the driver controls the start-up and operating cycle.
Normally, the supplier of the light point configures the drivers in a certain way and this can be agreed between the supplier and the customer, depending on the type of lighting and installation.
3.2. LEVEL 2: LIGHTING WITH ENERGY-SAVING SYSTEMS
The primary objective of using Level 2 lighting is to achieve energy savings by adapting consumption to the lighting needs of the installation during its operating hours.
Lighting with an energy-saving system allows for adjusting the brightness level of public lighting during certain time periods, rationalizing electricity consumption during periods of reduced lighting needs and achieving significant savings in electricity costs.
These systems reduce the power consumed by the light point during a specific nighttime period, and consequently, the illumination level in installations where a decrease in activity or usage characteristics justify it.
This rating is valid for any type of lamp that allows for a certain reduction in voltage or power supply without causing it to shut down or malfunction. Therefore, the energy savings of these systems will depend on the type of lamp used and its wattage, with LED lamps offering the greatest savings and metal halide lamps the least.
This voltage or power reduction can be implemented from the control center, affecting the entire installation, or locally at each light point.
Typically, all these systems, in addition to reducing voltage or power, also have a stabilization function to correct for overconsumption caused by voltages exceeding the nominal value.
For proper system control and to track the savings achieved, a remote management system based on the control unit at the control center must be installed.
3.2.1. Lighting with Flow Regulators and Stabilizers.
Lighting with flow regulators and/or stabilizers are those that, by varying the voltage of the electrical line from the control center, allow the light level to be adapted to the lighting needs, achieving energy savings.
Example of the cycle of different voltage levels in a flow regulator. Source: AFEISA.
A lighting system with flow regulators or stabilizers consists of the following components:
Control Center
• A flow regulator and/or stabilizer in the control center, which varies the voltage of the electrical line according to the commands received and maintains this voltage stabilized at all times.
• An astronomical clock or remote management equipment that sends the commands to turn the lights on and reduce their brightness to the flow regulator or stabilizer.
Maintenance and reprogramming of the flow regulators will be carried out at the control center.
Light Point
• Dimmers and/or stabilizers are commonly used with discharge lamps, especially sodium vapor lamps. This is because they use magnetic ballasts that adjust the input voltage to the output. They can also be used with LED technology, provided the LED driver has the option of dimming at the end of the line.
These types of systems are still installed in many public lighting systems, but nowadays, new installations are usually carried out with lighting systems that incorporate energy-saving systems at each light point, linked to the LED driver.
3.2.1.1. Remote Management Equipment
The flow regulator/stabilizer can be operated by an astronomical clock or by remote management equipment. In addition to its remote control functions explained in previous sections, it has additional functions designed to ensure energy efficiency management.
Examples include:
Recording electrical parameters and energy consumption.
The remote management equipment records measurements periodically, from the lighting switch-on to the switch-off, with a 15-minute recording period being the most common.
The main electrical parameters recorded for each phase are the three-phase active and reactive energy meters, voltage, current, active power, reactive power, and power factor.
Monthly average consumption of several control centers. Source: AFEISA.
It is also important to have operating hour counters for each of the relay outputs for the control of: astronomical lighting, the energy-saving system, and other control circuits.
Alarm control:
The remote management equipment will be able to detect alarms generated by the reading of electrical parameters, such as maximum and minimum setpoints for electrical parameters and/or the operating status of lamps, among others.
It must also monitor alarm inputs based on changes in the operating status of residual current devices (RCDs), contactors, manual switches, door controls, etc.
Recording of other parameters:
The remote management equipment will be able to read other sensors such as those for electrical insulation of the installation, environmental sensors, temperature, noise, etc.
3.2.2. Lighting with a Point-Based Energy Saving System
. The point-based energy saving system allows you to define the different light levels that the lighting will have at night, achieving significant energy savings during off-peak hours.
A point-based control system consists of the following components:
• An astronomical clock or remote management equipment in the electrical panel, which will control the
switching on of the control devices installed in each luminaire.
• A control device installed in each luminaire that can be programmed and reprogrammed later, with the initial light level and its different light levels throughout the
night.
Initially, the control device must be programmed with the time of day in which it will be installed in order to apply the hourly variations that occur during the night due to lighting needs.
The control device can be integrated into the driver itself.
It is recommended that this device have the option to read the current program, in order to check the programming later and to copy/paste the program from one device to another.
• A constant current driver in each luminaire to control the LED modules. The
driver must have communication capabilities (DALI or 1-10V) to communicate with the control device.
The main advantage of this system is that the control device does not require complex commissioning, and the lighting manufacturer ships the lighting fixtures with the control device already programmed according to the specifications of each lighting project. Furthermore, any modifications to the lighting level or nighttime lighting levels can be easily reprogrammed from the electrical panel or remotely if a remote management system is available.
Communication for reprogramming the different control devices from the electrical panel is carried out via the power line (PLC: Power Line Communication). This is a unidirectional PLC communication with no limit on the number of devices that can be communicated or maximum distances; as long as the power line is available, communication exists and reprogramming is possible. Reprogramming will be performed downstream of each contactor in the electrical panel. If you only want to reconfigure part of the lighting, leave open the contactors that control the luminaires you don't want to reconfigure.
In a point-by-point energy-saving system, communication via the electrical line between the electrical panel and the control devices for each luminaire is unidirectional. The configuration sequence is transmitted from the control center, and the control devices are reprogrammed to operate each luminaire.
The control device can be external and compatible with different drivers, using dimming protocols, or it can be integrated into the driver itself.
3.2.2.1. Regulation Protocols
Two widely used regulation protocols are available for controlling drivers: DALI and 1-10V. DALI is a bidirectional, identified digital signal capable of communicating with different lighting elements connected by a simple data bus (two wires), and logically forming independent groups (via software).
To control and parameterize DALI luminaires, a compatible control unit must be installed. These devices can generally manage up to 64 drivers (64 independent luminaires).
The 1-10V system, on the other hand, allows for the regulation of luminous flux, between approximately 10% and 100%, using an analog signal that reaches the equipment via an additional two-wire control line from the control center or the luminaire's control device. These control wires have positive and negative polarities, respectively, which must be respected during wiring.
The analog signal has a DC voltage value between 1V and 10V. The minimum light level is achieved with 1V or by short-circuiting the equipment's control input, and the maximum light level with 10V or by leaving the control input open.
The control line is used only for regulating the luminous flux. Switching the light on and off, which can occur at any point during regulation, is done via a switch located on the equipment's power supply line. Both lines, the control line and the power supply line, are electrically isolated from each other.
When the control line originates from the control center, the length of its wiring is limited by the voltage drop along its length. Therefore, the maximum distance is limited by the number of connected devices to be controlled. These devices determine the current through the line and the cross-section of the cable used.
18
3.2.2.2. Remote Management Equipment for Lighting Points
The incorporation of remote management equipment into a lighting system with energy-saving features at individual lighting points should, in addition to the functions described above for managing energy efficiency, facilitate monitoring the operation of the energy-saving system.
For example, the status of the luminaires can be monitored by measuring electrical consumption at the control center. If consumption falls below preset levels, the remote management equipment installed at the control center can alert maintenance services.
Another important feature is the ability to reprogram lighting points remotely via the power line, eliminating the need to travel to the control center.
3.3. LEVEL 3: REMOTE MANAGEMENT SYSTEM
Level 3 involves the installation and integration of the control and energy-saving equipment necessary for the overall management of the lighting installations, including the possibility of communication with other elements such as differential protection relays or utility company energy meters.
To achieve optimal installation performance and energy savings, control and operation can be implemented for each individual output line, even allowing for the control of each light point individually.
This type of control is what can generate maximum savings and optimization of the installation by integrating the control equipment of the different levels into a remote management platform.
3.3.1. Remote Management System for Control Centers
The remote management systems that manage the control units mentioned above must be designed to manage, in a scalable manner, projects ranging from small to large that require continuous management of these public lighting electrical installations.
These systems must provide detailed information about the facilities and the tools used to manage them. The data recorded by the remote control or management equipment is processed and transformed into practical information on the main operating parameters of the installation.
The information should be presented in an organized and simplified manner to facilitate decision-making, as these decisions contribute to a high degree of reliability in the measurements taken and the subsequent verification of the results obtained.
One of the advantages of this continuous management is that it allows us to visualize and constantly monitor fundamental aspects of the installation, such as operating events, electrical parameter variables, energy consumption, and alarms. This enables us to detect operational anomalies, verify their effects, and act immediately.
To facilitate management and simplify the monitoring of the installation's status, these systems must provide summaries of the daily and evolutionary operation of the facilities.
These reports will allow us to identify opportunities for improvement, helping us determine which management actions are most effective in enhancing the installation's performance.
The ability of these systems to utilize cartographic maps allows for the location of installations using interactive maps. This enables a simple visualization of the installations' geographic location, facilitating the monitoring of their status and their maintenance.
For energy efficiency management, the system provides analytical tools with multiple filtering formats and graphical representation of energy meters, both active and reactive, as well as hourly analysis of electrical parameters.
The remote management system will also monitor the correct operation of programmed maneuvers in the schedules of the various control centers.
The system must allow for the forcing of circuits to turn an installation on or off, as well as the activation of energy-saving systems; and the operation of special lighting such as beach or monument floodlights.
It is crucial that the remote control or management equipment be autonomous, meaning that even in the event of a loss of communication with the remote management system, it will still execute its programmed on/off schedules.
3.3.1.1. Communication with Control Centers
Information from the remote management equipment that controls each control center must be centralized, stored, and managed on a remote management platform. This information can be transmitted in two basic ways: via cable or radio frequency.
Currently, the most common form of wired communication is a fiber optic LAN, with the associated infrastructure and maintenance costs. Twisted-pair cable networks also exist, although their range is typically shorter.
Among radio frequency networks, initially the most common approach was to create a dedicated network of radio modems, but the costs of this type of infrastructure and the need for its maintenance led to the search for other alternatives.
The use of M2M networks from telephone operators is the most widely used option for communication with the remote management equipment in the control center. Its main advantage is the use of an existing network, which is maintained and updated by the operator, and it also allows data to be sent directly to a cloud platform. This means that a monthly fee must be paid to the operator, although the limited amount of data transmitted and the number of command centers in a city make these costs manageable.
M2M modem for communication between remote management equipment. Source: AFEISA.
There are other radio frequency communication alternatives that we will examine in more detail in the Wireless Technologies section.
To ensure data transmission and guarantee that it is safe from fraudulent use, it is advisable to use a connection over a network that incorporates mechanisms for establishing a secure connection and offers guarantees that the data is used exclusively by the application in question in a secure manner.
3.3.1.2. Remote Management Platforms for Control Centers
There are different platforms that allow for the management of street lighting, and these are open and interoperable to varying degrees. As we will discuss in the Interoperability section, it is advisable that the system used be integrable with horizontal Smart City platforms and interoperable with other solutions available to the city.
Other key aspects are ease of access, the incorporation of updates, and maintenance; these largely depend on the type of platform used.
There are basically two ways to host and access street lighting management platforms: they can be hosted by a cloud service provider or hosted on a local server, which may belong to the client.
In the case of a local server, the primary difference is that commissioning is much more complex and requires the collaboration of the IT department of the city council or end client. Furthermore, because it depends on these departments, the system will not function in the event of a server failure. Application administration and software updates must be coordinated between the user and the application provider. All data remains on the user's premises, and the user is responsible for data backups and security management. The user typically pays the software cost once, plus the additional cost of integrating the hardware and software infrastructure on the server. Support services (e.g., help desk) and software updates also incur additional costs.
In the case of a cloud service provider, access to the application is through encrypted user sessions using a secure connection (https). Application administration (updates, security, etc.) is handled by the remote management system provider. The client accesses the software through their profile, which uses a username and password. Depending on the application, different user roles or profiles may exist: technician, administrator, viewer, etc. Authenticated access must also be implemented to prevent unauthorized individuals or devices from accessing the network.
It is advisable that the systems implemented be sustainable over time, so having a Software as a Service (SaaS) solution is recommended, as it facilitates software updates, bug fixes, system improvements, and so on. Software updates ensure that systems are always robust and prevent future hackers from gaining access.
These cloud-based access platforms typically involve a service fee and are part of a SaaS (Software as a Service) contract.
3.3.1.3. Main Functions of a Remote Management System:
Recording Electrical Parameters and Energy Consumption.
Monitoring consumption from the lighting control panel is widespread and makes sense for both the maintenance/installer and the city council for the energy management of their installation.
The main electrical parameters recorded can be, for each phase: three-phase active and reactive energy meters, voltage, current, active power, reactive power, and power factor.
It is also useful to have operating hour counters for each of the relay outputs for the control of: the lighting's astronomical time zone, the energy-saving system, and other control circuits.
Alarm Control.
Remote control or management equipment can detect alarms generated by the reading of electrical parameters: maximum and minimum setpoints for electrical parameters, operating status of lamps, etc.
It should also monitor alarm inputs based on changes in the operating status of residual current devices (RCDs), contactors, manual switches, door controls, etc.
Recording of other parameters:
The remote management units can read other sensors such as the installation's electrical insulation, environmental probes, temperature, noise, and others.
Communication with the control unit:
Communication must be online, with the system receiving priority alarms in real time. Other alarms and events can be downloaded periodically, for example, once a day.
It is also essential that the remote control or management equipment has the ability to send an alarm to the system indicating a lack of power at the control center. In the event of a communication failure, it is necessary to differentiate whether it is due to a lack of power at the panel, a priority alarm, or a communication problem.
3.3.1.4. Other Functions and Remote Management Systems:
Control Systems Based on Ambient Natural Light.
Systems exist that control the operation of remote management centers based on online monitoring of the ambient light level in a city or area. This allows for automatic action in critical or special situations where weather phenomena can affect the level of natural light in different city streets, making the use of artificial lighting necessary.
This type of solution works similarly to a photocell, but uses high-precision lux sensors that detect an illuminance level and send a command to the remote management system to force the switching on or off of the lighting in all assigned lighting panels. If no command is received, the remote management equipment in the control center performs the astronomically programmed switching on and off.
Similarly, if weather conditions are favorable, commands are sent to the remote management system to delay the switching on time or advance the switching off time of the corresponding lighting panels.
These solutions typically allow for the definition of different zones with varying levels of intervention, enabling adjustments to artificial lighting in areas where ambient light levels decrease or increase.
regulate
light intensity based on statistics obtained from traffic counts using various techniques such as radar, machine vision, pneumatic traffic counting, and others.
This information is processed by the remote management system, which then adjusts the lighting according to the parameters set for the collected data.
3.3.2. Two-Way Remote Management of Lighting Points
The difference between the energy-saving systems for lighting points discussed in level 2 and remote management systems for lighting points lies in two-way communication with the luminaire.
Two-way lighting control solutions allow connectivity with the luminaire, providing complete control over its operation and key electrical parameters such as current, voltage, and power consumption, as well as operational alarms should they occur. This enables efficient management of outdoor lighting installations.
Furthermore, the ability to communicate with the driver via the main communication standards, DALI and 1-10V, also allows for the incorporation of energy-saving functions and full control over lighting dimming.
It is also important to note that the ever-increasing demand for remote management systems is driving economies of scale, resulting in lower prices for this technological equipment. The main differences between the various remote management systems for lighting points stem from the technology used to communicate with the lighting point. The communication technologies currently available are detailed below.
3.3.2.1. Remote management of light point by PLC
Remote management through the cable (Power Line Communication), that is, using the power supply circuits of the luminaires, to communicate bidirectionally through a carrier wave.
PLC (Power Line Control) systems have the advantage that, since information is transmitted over the existing cable, the luminaire does not need to be modified to enable communication.
Key strengths include:
• Utilization of existing network infrastructure.
• Fast response time with new lines.
• Immune to radio interference.
• Reduced susceptibility to signal jammers.
• Installation of the carrier-based communication module at the control center simplifies
maintenance.
• No need to add or maintain additional infrastructure beyond that of the control centers.
Among the main weaknesses are:
• Requires the installation of accessory components such as filters that need maintenance.
• More expensive equipment due to the high loads involved.
• Sensitivity to electromagnetic noise generated in the city (machinery, trams,
streetlights).
• Cable-to-cable crosstalk and interference (variable depending on the cable's condition).
• Carrier bandwidth limitations.
3.3.2.2. Remote Management of Lighting Points via RF.
Remote management via radio waves (Radio Frequency) involves using specific radio frequencies and installing a dedicated communications network above the electrical grid.
The benefits of wireless connectivity include savings in cabling and flexibility in deploying and installing control systems, enabling control of road infrastructure that was previously inefficient using wired cabling.
Key advantages include:
• The remotely managed area is independent of the electrical configuration (circuits).
• Recommended for locations with unstable electrical networks.
• Requires no new wiring (it is independent of the cable's condition) or additional components such as
filters.
• System expandability for integrating other sensors throughout the city.
The main weaknesses include:
• The need to incorporate and maintain additional infrastructure such as concentrators, gateways, repeaters, etc.
• Requires prior calculation of coverage, sizing, etc.
• Radio obstacles must be circumvented.
• Areas with jammers.
In radio systems, in most cases, a physical output must be enabled to allow communication between devices, either through antennas or predefined standards. This can modify the isolation, immunity, and certification of the luminaire.
3.3.2.2.1. Integration in Luminaires.
One alternative is to use a hardware integration standard in the luminaire, which ensures that the entire luminaire can be certified to a specific standard and subsequently incorporate certified compatible modules, as well as replace them with others as technology evolves.
Regarding standards, there are basically two systems that are becoming dominant: NEMA and ZHAGA. These standards allow remote management systems to be separated from the luminaires, facilitating the expansion of solutions since they are not subject to integration within the luminaires. This allows both installers and end customers (municipalities, provincial councils, regional councils, etc.) to have compatible equipment.
• NEMA System: The National Electrical Manufacturers Association (NEMA) is an American industrial association, created on September 1, 1926. This organization is responsible for numerous common industry standards used in the electrical field. Among others, NEMA has established a wide range of standards for electrical equipment encapsulations. In the case of lighting, the standard used is ANSI C136.41, which allows for plug-and-play connectivity of the equipment. Through these encapsulations used for incorporating photocells, remote management equipment can be implemented to improve energy efficiency with the dimming and control capabilities they provide. This is achieved through 0-10 VDC or DALI (Digital Addressable Lighting Interface) regulation. Interconnection is achieved through a twist-lock system. The most widespread system currently, given its versatility, is the NEMA ANSI C136.41 7-pin, as it allows for both 1-10V and DALI regulation. It should be noted that these are 120 or 240 VAC connections, which implies electrical safety requirements that must be taken into account.
• ZHAGA System: The Zhaga Consortium is an international organization, founded in February 2010, that establishes industry specifications for interfaces for components used in LED luminaires. The Zhaga specifications, which are called The “Books” address electrical, mechanical, optical, thermal, and communication interfaces, enabling component interoperability. The Zhaga community includes luminaire manufacturers, lamp manufacturers, LED module producers, and companies that supply components and materials to the lighting industry. It should be noted that these are 24 VDC connections, i.e., Safety Extra Low Voltage.
Today, with the rise of Smart Cities, more and more municipalities are becoming interested in existing control methods. A recent report by Navigant Research stated, “Smart street lighting is being recognized by many city leaders as the first step toward developing smart cities.” In this search for systems, NEMA has the advantage of being a technology with a long and thoroughly tested history. On the other hand, the advantages of the Zhaga system should not be underestimated; it reduces the size of the nodes and guarantees greater electrical safety. This point is very important for the aesthetics of the luminaires, which ultimately define the appearance and character of cities. Despite Despite all this, there are still many nodes that are incorporated within the luminaires, as design is a value to be taken into account by both administrations and architects.
3.3.2.2.2. Wireless Technologies
Given the continuous emergence of new wireless developments and the multitude of technologies available—Wi-Fi, NB-IoT, Zigbee, Bluetooth, Bluetooth Mesh, LoRa, Sigfox, 4G/5G, 6LoWPAN, etc.—and the fact that none has yet become dominant, choosing one can be challenging. We can primarily group networks into:
• Licensed (NB-IoT (country-specific), Sigfox, 2G, 3G, 4G, 5G)
Access based on tariffs.
The use of this type of communication, typically direct to the cloud (licensed technology), makes it very useful and secure. Since gateways are not required, its high transmission speed, and the fact that this technology, whether 2G, 3G, or 4G, covers almost the entire planet, makes it one of the most widely used communication methods in certain vertical platforms for Smart City management. The unique fact that public lighting encompasses a large number of devices makes communication costs very high, and therefore this type of technology is difficult to implement on a large scale, although it should be noted that the evolution of 5G may change this.
• License-free (ISM Applications) (Wi-Fi, NB-IoT, Zigbee, Bluetooth, Bluetooth Mesh, LoRa, 6LoWPAN, etc.) Although in most cases the license fee is paid when purchasing the device, since the manufacturer pays a cost or royalty to the organization or association that manages the technology.
Free access granted to all users. The main frequency bands by region are:
- Europe: 315MHz, 433MHz, 868MHz, 2.4GHz
- Asia-Pacific: 315MHz, 2.4GHz
- Middle East and Africa: 433MHz, 2.4GHz
- New Zealand: 864-868MHz, 915-928MHz, 2.4GHz - America and Asia: 915MHz, 2.4GHz
- India: 865-867MHz, 2.4GHz
- Australia: 915-928MHz, 2.4GHz - Japan: 920MHz, 2.4GHz
We can now group the technologies framed within the ISM bands:
• Technologies based on LPWA (Low Power Wide Area Network)
- LoRaWAN: LoRaWAN networks are specific networks that are They deploy ad hoc networks to implement low-data-throughput equipment. The network belongs to the company deploying it and is primarily used for IoT devices. If one repeater fails, the entire network goes down. In other words, the network does not rely on other technologies to transmit data, such as 3G/4G/GPRS, which depend on telephone operators, although gateways can be installed for this purpose.
- Sigfox: This is a solution from a global network operator (Abertis/Cellnex) and implements wireless networks to connect low-power devices. It has mainly been used for electricity meters, alarm systems, and smartwatches, which need to be continuously powered on and sending small amounts of data.
• Radio frequencies based on the IEEE 802.15.X standard
- Bluetooth: establishes short-range communication at 1 Mbps. Bluetooth is based on the IEEE 802.15.1 standard. It is designed for small personal computing devices and can be a solution for small-scale communication (for example, a driver to check and program a light fixture on-site or in short-range areas). It uses the 2.4 GHz band.
- Wi-Fi: is based on the IEEE 802.11 standard. It is very easy to install and manage, and many devices already have built-in Wi-Fi antennas for integration. Its main drawback is the short network range. Wi-Fi Max was developed to extend this range, but the main problem is the high power consumption of nodes with this type of antenna, resulting in wasted bandwidth if such a network is established for low-level devices, such as nodes in a smart city network. It typically uses the 2.4 GHz or 5 GHz bands.
- ZigBee: is based on the IEEE 802.15.4 wireless networking standard. Its main characteristics are low power consumption, a robust mesh network, easy integration, and significant global development. It is primarily intended for home use. It can utilize the 868 MHz (Europe) and 915 MHz (USA) bands, although 2.4 GHz is the most common.
LowPAN, also based on the IEEE 802.15.4 standard, features a mesh network, low power consumption, and better IoT compatibility, enabling IPv6 and direct communication between devices and other IP devices. It offers frequency band freedom.
Considering the topology of public lighting, important factors include:
• Spacing between light points (between 20 and 40 meters)
• Communication obstacles such as buildings, trees, etc. • Weather conditions such as rain and fog.
This makes it advisable to use technologies that operate in sub-GHz bands (≤1GHz), specifically 433MHz, 868MHz, and 915MHz (LoRaWAN or SigFox), as they offer a range two to three times greater than standards operating at 2.4GHz. Implementation costs are relatively low, and energy consumption is minimal. These technologies are regulated by country, so it's essential to verify that the solution's frequency complies with current legislation. Furthermore, due to the inherent nature of the technology, Bluetooth or Wi-Fi-based solutions have a shorter range, requiring the addition of gateways.
Therefore, understanding the network configuration is crucial to ensuring communication quality. There are two main types:
• Direct communication between a series of points and the gateway individually requires detailed, individual configuration and is therefore more expensive. Additionally, the points must have a clear line of sight to the concentrator or be located close to it.
• Mesh communication: Each device can both transmit and forward information, skipping signals and increasing the distance to the gateway. We can control between 150 and 300 luminaires (depending on the terrain's oleography and the installation's topology) that are separated from each other.
Expanding this type of deployment simply requires adding more gateways and deploying a similar network around them.
3.3.2.3. IoT-Based Remote Management of Lighting Points:
Remote management of each lighting point via the cellular network (mobile phone network), i.e., by installing and subscribing to a SIM card at each lighting point.
Among the strengths of this type of remote management, we can point out:
• Cellular networks maintained by telephone operators
• Reduction of redundant elements (no need to install and maintain
additional infrastructure such as concentrators/gateways). The main weaknesses are:
• The lighting point is fixed and cannot be moved in search of better coverage.
• Network and coverage depend on the total number of users, as well as the operator.
• Fixed communication costs for each lighting point.
• Dependence on the operator and captive customer; to change operators, the SIM card must be replaced
.
• Potential cyberattacks and additional communication costs.
3.3.3. Other Functionalities of Remote Lighting Management
In addition to the functionalities already mentioned, remote lighting management systems may include additional elements that provide other functionalities beyond those discussed.
3.3.3.1. Geolocation
Certain remote control devices have geolocation via GPS communication to allow for subsequent equipment tracking and the planning of adjustments based on their location. Geolocation can be achieved either because the luminaire has a GPS chip or through an external tool that geolocates the device using its coordinates.
Source: Sinapse
When evaluating these technologies, aspects such as the additional cost of integrating this technology into each device must be considered. The mobility of the luminaires should also be taken into account, as these elements are generally static. Finally, the accuracy of the GPS devices must be considered, as there are always margins of error.
3.3.3.2. Sensors
Streetlights, by their very nature—being found throughout the city, every few meters (30-40 meters), and having access to mains electricity—are an ideal location for incorporating new IoT devices to collect city data. These
sensors can be divided into:
• Sensors/actuators that interact with the streetlights
- Noise sensor with increased brightness
- Motion sensor
• Sensors/actuators unrelated to the operation of the lighting
- Airborne particles, rain gauge, humidity, etc.
3.3.4. Remote Management System for Lighting Points
As we have seen, there are different ways to send and receive data from lighting points depending on the type of technology used in the connected lighting system.
In the case of IoT technology with 3G/4G/5G communication, each lighting point will communicate directly with the cloud-based remote management platform.
With other technologies, the data will connect to a concentrator that will transmit the information to the remote management platform. This can be done through a communication system using: wired (Ethernet/Fiber), wireless (3G, LTE, 4G), or WiMAX.
In PLC-based technology, the concentrator is located in the control center and typically communicates with the control center's remote management equipment to send information to the remote management platform.
In RF-based technology, the concentrators are located at different points within the installation and typically communicate independently of the control center's remote management equipment to send information to the remote management platform. Remote
management systems for individual lighting fixtures usually incorporate a remote management system for the control center.
There are different types of point-to-point remote management systems with varying levels of control capacity. However, they all share some basic functionalities, such as:
• The ability to create groups of luminaires for remote management.
• The ability to individually switch off/dim each light point.
• Programming for each light point or group.
• Configuration of groups of luminaires for remote management.
• The ability to vary dimming settings by group/time and according to calendars.
• The ability to create specific dimming curves for holidays and events.
• Measurement of active power for each light point.
• Detection of individual lamp failures to improve service quality and maintenance.
Currently, many tenders require point-to-point consumption monitoring. In this respect, point-to-point monitoring allows you to obtain a very large amount of information, such as:
• Knowing if dimming is taking place.
• Knowing the status of the luminaires.
• Knowing if there are voltage spikes.
All of this also requires support for managing all this data, as this information overload can become a handicap when managing the installation. Furthermore, this consumption monitoring often results in higher hardware costs, which increases the installation cost, and therefore, this type of consumption monitoring is not always necessary. Nevertheless, it is important to emphasize that in certain circumstances, point-to-point consumption monitoring can provide highly valuable information.
Adapting Technologies to Specific Needs:
The technologies described above are commonly applied in various lighting applications, including:
• Street lighting.
• Residential lighting.
• Park and garden lighting. •
Commercial lighting.
• Industrial lighting.
• Decorative lighting. •
Festive and Christmas lighting.
• Sports area lighting.
• Others.
The technology chosen will depend on the type of lighting, but above all on the specific needs and performance requirements of each installation. Therefore, we will now link the different performance levels with the available technologies for each of the indicated categories.






As detailed in the table, the main aspects to consider when choosing a current or future remote management system are:
• User-owned network or paid network.
• Network reach and ease of expanding control units (scalability).
• Number of gateways per light point and redundancy in case of network failure.
• Amount of data transmitted and the possibility of remote reprogramming or updating.
• Option to connect other sensors or devices.
• Network security against cyberattacks.
Other aspects to consider when choosing a technology and/or control unit are:
• The integration of the control unit, whether it must be installed inside the luminaire or allows connection to the luminaire via a NEMA or ZHAGA enclosure.
• Other additional costs, besides direct expenses for communications, hosting, etc., such as the added cost of maintenance and operation of non-redundant, non-scalable systems, which are less secure against cyberattacks, etc.
• The contribution each manufacturer makes to their solutions, with their knowledge and experience. Therefore, aspects such as years of experience, after-sales service and personnel, system implementation, etc., must be evaluated. In many cases, this can lead to the successful implementation and continuity of the system, as well as future savings in maintenance costs.
Regulations and Certifications
CE Marking: This means that the product meets the safety requirements for marketing and can circulate freely within the European Union. CE marking for luminaires is governed by Directive 89/106/EC and the European Construction Products Regulation (EU) No 305/2011.
There are two ways to obtain CE marking: through third-party certification or through self-certification. In the case of self-certification, the manufacturer certifies that their product complies with the applicable regulations, based on tests carried out in their own or external laboratories on sample luminaires or prototypes. However, for the assurance of regulatory compliance, guidelines must be followed, for which there are laboratories accredited by national accreditation bodies that guarantee compliance. CE marking for luminaires does not imply control of the entire production process.
To ensure that the tests are carried out in accordance with the regulations, national accreditation bodies were created.
ENAC: National Accreditation Entity. It is the entity designated by the State to operate in Spain as the sole national accreditation body, in accordance with Regulation (EC) 765/2008, which governs the operation of accreditation in Europe. ENAC Accreditation: Accreditation is the internationally established tool that provides end users with confidence in the correct implementation of CE marking through conformity assessment, a procedure that includes testing, calibration, inspection, certification, and verification, among other services.
When evaluating test reports for conformity, it is recommended that they be endorsed by a Conformity Assessment Body (CAB) accredited by ENAC or an equivalent European body. If a test document is prepared by an ENAC-accredited laboratory or another accreditation body in accordance with Regulation (EC) No 765/2008 of the European Parliament and of the Council of 9 July 2008, laying down requirements for accreditation and market surveillance relating to the placing of products on the market, the accreditation body's seal will appear on the report, providing traceability of the test and an electronic signature that guarantees the document's authenticity. It is mandatory that the CAB (laboratory) be accredited for the standard to be certified; verifying whether the scope of accreditation includes the standard in question is essential. Test reports do not guarantee compliance with all applicable regulations, and it remains the manufacturer's responsibility to comply with current standards.
A product certificate is a document in which an independent body, called a certification body, verifies and assures that the products supplied by a manufacturer conform to the technical requirements of one or more standards. In these cases, the notified certification body guarantees the product's regulatory compliance.
It is important to understand the differences between a Directive and a Standard. A directive approved by the European Parliament becomes a mandatory requirement, but it must be translated into applicable regulations. It is the standards, through testing, that demonstrate compliance with the directive.
42
5.1. REGULATIONS AND OPERATION OF THE INSTALLATION
Although an outdoor lighting installation provides light energy, it uses electrical energy. Therefore, regulations carefully consider both aspects: the lighting installation and the electrical installation. Furthermore, they are considered from two perspectives: safety and functionality.
For example, lighting safety means that the installation must switch on every night at sunset and maintain a minimum light level appropriate for the type of road where it is used. Electrical safety means, for example, that the installation and equipment have adequate electrical protection against direct and indirect contact.
The functional aspects of a lighting installation address issues such as light pollution and stray light, while the functional aspects of the electrical installation include, for example, energy savings and energy efficiency.
In current Spanish regulations regarding the aspects discussed, the main standard for the electrical safety of lighting installations is Royal Decree 842/2002 on the Low Voltage Electrotechnical Regulations (hereinafter REBT). For other aspects, Royal Decree 1890/2008 on the Energy Efficiency Regulations for Outdoor Lighting Installations (REEA) is also relevant.
We must also consider the various European directives that have been adopted in Spain and, as such, form part of Spanish regulations. These mostly apply to the equipment and components used in installations, such as luminaires and their components, supports, cables, lighting control panels and their components, etc. Section 8.2 delves deeper into these directives and standards.
Regarding UNE, EN, IEC, ISO, and other standards, it is important to note that only those specifically designated as mandatory in officially published directives or regulations are legally binding.
The remaining standards are a proven technical reference endorsed by standardization bodies, which we can include as a technical requirement in a public tender.
5.1.1. Low Voltage Electrical Regulations (REBT)
Published by Royal Decree 842/2002 of August 2, 2002, these regulations have undergone some changes since then, such as the inclusion of ITC-BT-52 on Electric Vehicle Charging Infrastructure, published in Royal Decree 1053/2014, and the update of ITC-BT-02 on mandatory reference standards, published in BOE-A-2020-612. The latest updates can be found in the BOE.
Outdoor lighting installations must comply with all applicable general requirements of the REBT, and in particular, Article 9 and ITC-BT-09, as well as the standards included therein, but in their current versions.
Therefore, a table updating the standards corresponding to ITC-BT-09, in accordance with the recent update of ITC-BT-02, is included below.
It should be noted that this is the situation as of the date of this report, but that the standards are under continuous review and development. Therefore, the current versions can be consulted on the UNE website. This is the case, for example, with UNE-EN 60298-2-5:2015 for projectors, which has replaced UNE-EN 60598-2-5:1999. It is
also important to consider the Technical Application Guides for the various ITC-BT (Technical Instructions for Low Voltage) published by the Ministry of Industry. As indicated in Article 29 of the REBT (Low Voltage Electrotechnical Regulations), these guides are a practical application of the corresponding ITC-BT but are non-binding, meaning compliance is not mandatory. For outdoor lighting installations, the current edition is GUIDE-BT-09: September 2004. Revision: 1.
For projects in other countries, the corresponding national regulations must be taken into account, although the IEC 60364 series of international standards and its European equivalent, the HD 60364 series for low-voltage electrical installations, should be highlighted.
In this regard, UNE-HD 60364-7-714:2013 on Requirements for outdoor lighting installations, which is equivalent to IEC 60364-7-714:2011 and HD 60364-7-714:2012, is also a standard that can be considered when drafting the technical requirements for both national and international tenders.
For festive street and Christmas lighting, as well as for other temporary electrical installations, ITC-BT-34 of the REBT (Spanish Low Voltage Electrotechnical Regulations) must also be applied.
5.1.2. Energy Efficiency Regulations for Outdoor Lighting
Published by Royal Decree 1890/2008 on November 14, 2008, although at the time of writing this document, the publication of an important update resulting from the implementation of LED technology in outdoor lighting installations was pending.
The fundamental objective of the REEA (Regulations for Outdoor Lighting Installations) is to establish the technical design, implementation, and maintenance requirements for outdoor lighting installations, with the aim of improving efficiency and energy savings. Its scope of application covers installations exceeding 1 kW, in accordance with the REBT (Low Voltage Electrotechnical Regulations) and ITC-BT-09 (Technical Instruction for Low Voltage Electrotechnical Regulations).
In addition to the functional aspects of the electrical installation for achieving energy efficiency, it also includes lighting functional aspects due to their direct relationship with energy efficiency.
This document focuses on the control of the installation and its connected components, regardless of their suitability from a lighting perspective. Therefore, we concentrate on Article 8 and ITC-EA-04, paying particular attention to the section on Control Systems.
It is also important to consider the Technical Application Guides for the various ITC-EA regulations published by the Ministry of Industry, which, as indicated, are practical applications of the corresponding ITC-BT regulations but are non-binding, meaning they are not mandatory. In the case of the ITC-EA-04 guide, the current edition is GUIDE-EA-04: May 2013; Revision: 1.1.
5.2. PRODUCT STANDARDS
Currently, lighting systems include numerous remote management, radio, and lighting systems, making a thorough evaluation of all applicable standards essential. Different directives apply depending on the product and system.
5.2.1. Luminaire
5.2.1.1. Electrical Safety
• UNE-EN 60598-1. Luminaires. General requirements and testing.
• UNE-EN 60598-2-3. Luminaires. Particular requirements. Street lighting luminaires.
• UNE-EN 60598-2-5. Luminaires. Particular requirements. Floodlights.
• UNE-EN 60598-2-20. Luminaires. Part 2-20: Particular requirements. String lights.
• UNE-EN 60598-2-21. Luminaires. Part 2-21: Particular requirements. Light cords.
Luminaire.
5.2.1.2. Electromagnetic Compatibility
• UNE-EN 61547. General purpose lighting equipment. EMC immunity requirements.
• UNE-EN 61000-3-2. Electromagnetic compatibility (EMC). Part 3-2: Limits. Limits for
harmonic current emissions (equipment with 16A input current per phase)
• UNE-EN 61000-3-3. Electromagnetic compatibility (EMC). Part 3: Limits. Section 3: Limitation of voltage variations, voltage fluctuations and flicker in low-voltage public supply networks for equipment with 16A input current per phase and not subject
to conditional connection.
• UNE-EN 55015. Limits and measurement methods for the radio interference characteristics
of lighting and similar equipment.
5.2.1.3. Human Exposure
• UNE-EN 62493. Evaluation of lighting equipment with regard to human exposure to electromagnetic fields.
5.2.1.4. Optical Testing and Photobiological Safety
• UNE-EN 13032-1. Light and lighting. Measurement and presentation of photometric data of lamps and luminaires. Part 1: Measurement and file format.
• UNE-EN 13032-4. Light and lighting. Measurement and presentation of photometric data. Part 4: LED lamps, LED modules and LED luminaires.
• UNE-EN 62471. Photobiological safety of lamps and lamp-using equipment.
• IEC TR 62778. Application of IEC 62471 for the assessment of blue light hazard to light sources
and luminaires.
5.2.1.5. Functional requirements and performance
• UNE-EN 62722-1. Performance of luminaires. Part 1: General requirements
• UNE-EN 62722-2-1. Performance of luminaires. Part 2-1: Particular requirements for
LED luminaires
• UNE-EN 62262 (UNE-EN 50102). Degrees of protection provided by enclosures for
electrical equipment against external mechanical impacts (IK code)
• Section 9.2 UNE-EN 60598-1. Luminaires. General requirements and testing. (IP rating)
5.2.2. Drivers/Power Supplies
5.2.2.1. Electrical Safety
• UNE-EN 61347-1. Lamp control devices. Part 1: General requirements and safety requirements.
• UNE-EN 61347-2-11. Lamp control devices. Part 2-11: Particular requirements for miscellaneous electronic circuits used with luminaires.
• UNE-EN 61347-2-13. Lamp control devices. Part 2-13: Particular requirements for DC or AC powered electronic control devices for LED modules.
5.2.2.2. Functional Requirements
• UNE-EN 62384. DC or AC powered electronic control devices for LED modules. Performance requirements.
46
5.2.3. Communication Modules / Remote Management Equipment
5.2.3.1. Electrical Safety
• UNE-EN 62368-1. Audio and video equipment, information and communication technology equipment. Part 1: Safety requirements.
• UNE-EN 60950-22. Information technology equipment. Safety. Part 22: Equipment for outdoor installation.
• UNE-EN 61010-1. Safety requirements for electrical measuring, control and laboratory equipment. Part 1: General requirements.
5.2.3.2. Electromagnetic Compatibility
• UNE-EN 60870-2-1 - Telecontrol equipment and systems. Part 2: Operating conditions. Section 1: Power supply and electromagnetic compatibility.
• UNE-EN 61326-1 - Electrical equipment for measurement, control and laboratory use. Electromagnetic compatibility (EMC) requirements. Part 1: General requirements.
• ETSI EN 303 446-1 - Electromagnetic Compatibility (EMC) standard for combined and/or integrated radio and non-radio equipment; Part 1: Requirements for equipment intended for use in residential, commercial and light industrial locations.
• ETSI EN 303 446-2 - Electromagnetic Compatibility (EMC) standard for combined and/or integrated radio and non-radio equipment; Part 2: Requirements for equipment intended for use in industrial locations.
• ETSI EN 301 489-1 - ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonized Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU and the essential requirements of article 6 of Directive 2014/30/EU.
• ETSI EN 301 489-3 - ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Devices (SRD) operating on frequencies between 9 kHz and 246 GHz; Harmonized Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU.
• ETSI EN 301 489-17 - ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for Broadband Data Transmission Systems; Harmonized Standard for ElectroMagnetic Compatibility.
• ETSI-EN 301 489-19 - ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 19: Specific conditions for Receive Only Mobile Earth Stations (ROMES) operating in the 1.5 GHz band providing data communications and GNSS receivers operating in the RNSS band (ROGNSS) providing positioning, navigation, and timing data; Harmonized Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU.
• ETSI EN 301 489-52 - Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 52: Specific conditions for Cellular Communication Mobile and portable (UE) radio and ancillary equipment; Harmonized Standard covering the essential requirements of article 3.1(b) of Directive 2014/53/EU.
5.2.3.3. Radio
• ETSI EN 300 330 - Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonized Standard covering the essential requirements of article 3.2 of the Directive 2014/53/EU.
• ETSI EN 300 220-2 - Short Range Devices (SRD) operating in the frequency range 25 MHz to 1 000 MHz; Part 2: Harmonized Standard for access to radio spectrum for non-specific radio equipment.
• ETSI EN 300 328 - Wideband transmission systems; Data transmission equipment operating in the 2.4 GHz ISM band and using wide band modulation techniques; Harmonized Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU.
• ETSI EN 300 440 - Short Range Devices (SRD); Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Harmonized Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU.
• ETSI EN 301 893 - 5 GHz RLAN; Harmonized Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU.
• ETSI EN 301 511 - Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonized Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU.
• ETSI EN 301 908-1 - IMT cellular networks; Harmonized Standard for access to radio spectrum; Part 1: Introduction and common requirements.
• ETSI EN 301 908-2 - IMT cellular networks; Harmonized Standard covering the essential requirements of article 3.2 of the Directive 2014/53/EU; Part 2: CDMA Direct Spread (UTRA FDD) User Equipment (UE).
• ETSI EN 301 908-13 - IMT cellular networks; Harmonized Standard for access to radio spectrum; Part 13: Evolved Universal Terrestrial Radio Access (E-UTRA) User Equipment (UE).
• ETSI EN 301 908-25 - IMT cellular networks; Harmonized Standard for access to radio spectrum; Part 25: New Radio (NR) User Equipment (UE).
5.2.3.4. Human Exposure
• UNE-EN 62479 - Assessment of the conformity of low-power electrical and electronic equipment with the basic restrictions on human exposure to electromagnetic fields (10 MHz - 300 GHz).
• UNE-EN 62311 - Assessment of electrical and electronic equipment with respect to the restrictions on human exposure to electromagnetic fields (0 Hz - 300 GHz).
5.2.4. LED Module
5.2.4.1. Electrical safety
• UNE-EN 62031. LED modules for general lighting. Safety requirements.
5.2.4.2. Functional requirements/performance
• UNE-EN 62717. LED modules for general lighting. Performance requirements.
5.2.5. Columns and Poles
Mechanical requirements:
• UNE-EN 40-4:2006: Lighting columns and poles. Part 4: Requirements for lighting columns and poles of reinforced and prestressed concrete.
• UNE-EN 40-5:2003: Lighting columns and poles. Part 5: Requirements for steel lighting columns and poles.
• UNE-EN 40-6:2003: Lighting columns and poles. Part 6: Requirements for aluminum lighting columns and poles.
• UNE-EN 40-7:2003: Lighting columns and poles. Part 7: Requirements for lighting columns and poles of fiber-reinforced polymer composites.
• UNE-EN 1090-1:2011+A1:2012: Execution of steel and aluminum structures. Part 1: Requirements for the conformity assessment of structural components.
5.2.6. Electrical cabinets
5.2.6.1. Electrical safety
• UNE-EN 61439-1. Low-voltage switchgear and controlgear assemblies. Part 1: General rules.
• UNE-EN 61439-2. Low-voltage switchgear and controlgear assemblies. Part 2:
Power switchgear and controlgear assemblies.
5.2.6.2. Electromagnetic compatibility
• UNE-EN 61439-1. Low-voltage switchgear and controlgear assemblies. Part 1: General rules.
• UNE-EN 61439-2. Low-voltage switchgear and controlgear assemblies. Part 2:
Power switchgear and controlgear assemblies.
5.2.7. Combined Systems.
The certification of combined systems will depend on the elements that comprise the system, thus defining a set of tests that must comply with the most restrictive standards for the elements that make up the system. It should be noted that the sum of the CE markings of each individual element can never be considered sufficient to validate the certification of the entire system.
6. Points to consider when drafting tender documents
6.1. INTEROPERABILITY
One of the important premises when choosing a remote management system is its interoperability with other platforms, both for remote management systems and higher-level Smart City platforms. This is a key factor for municipalities because, if the system is open, the municipality will not be tied to a specific technology provider.
To facilitate the integration of different platforms, Application Programming Interfaces (APIs) are becoming increasingly prevalent, making it easy for different systems to integrate with other platforms. The ease of API integration often depends on the protocol used, as a standard protocol provides IT staff with the necessary resources for integration. Some examples of standards include:
• MQTT (Message Queue Telemetry Transport), a protocol used for machine-to-machine (M2M) communication in the Internet of Things. The API is freely available and defines connectors that allow easy integration with REST services: http://docs.oasis-open.org/mqtt/mqtt/v3.1.1/mqtt-v3.1.1.html
• The 6LowPAN (IPv6 over Low Power Wireless Personal Area Networks) protocol is an open standard defined by the IETF (Internet Engineering Task Force). This standard enables the use of IPv6 over networks based on the IEEE 802.15.4 standard, allowing devices to communicate directly with other IP devices.
• Another alternative is to integrate the remote management system with a series of open platforms that are becoming national and international benchmarks, such as:
• Sentilo: an open-source sensor and actuator platform designed to adapt to the Smart City architecture of any city seeking openness and easy interoperability. http://www.sentilo.io/wordpress/
• FIWARE: This is a platform, driven by the European Union, for the development and global deployment of Future Internet applications. FIWARE aims to provide a fully open, public, and free architecture, as well as a set of specifications that allows developers, service providers, companies, and other organizations to develop products that meet their needs while remaining open and innovative. https://www.fiware.org/
• WI-SUN: The Wi-SUN Alliance is a global ecosystem of member companies that seeks to accelerate the implementation of Field Area Networks (FANs) based on open standards and the Internet of Things (IoT). https://www.wi-sun.org/
• TALQ Consortium: Its objective is to define a globally accepted smart city protocol so that central management software can configure, control, order, and monitor heterogeneous smart city device networks.
6.2. TRAINING
An important aspect to consider is receiving adequate training on the use and operation of the hardware and software from the platform manager or equipment supplier. This training should cover the following aspects:
• Installation, replacement, and maintenance of the devices.
• Use of the remote management software.
• Maintenance of the communications infrastructure and the remote management platform.
The required training levels will depend on the type of control equipment, energy-saving system, and remote management platform chosen. In many cases, training can be conducted online, while in others, in-person training is required.
If a training plan is necessary, it should be properly planned and its cost assessed.
6.3. MAINTENANCE OF EQUIPMENT AND REMOTE MANAGEMENT SYSTEMS
Another important aspect to consider is the maintenance service for the equipment and the remote management platform. This is not a public lighting maintenance service; that is, it does not replace municipal maintenance companies/crews, but rather serves as a support tool for these services.
The different levels of support can be classified as follows:
• LEVEL 1 (L1): This is the support offered by the public lighting maintenance company and involves on-site work for equipment replacement, inspection, and verification of physical components. At this level, the company supplying the remote management equipment and/or platform can provide online support for equipment diagnosis, configuration, and/or updates, as well as on-site repair or upgrade services.
• LEVEL 2 (L2): This level is the support service for the maintenance and updates of the remote management platform, offered by the company that manages the platform (SaaS).
• LEVEL 3 (L3): This service is offered by the hardware supplier and includes online support and repair services from Level 1, along with the Level 2 service. This model has the most potential for future growth, as it allows for the future evolution of the remote management system with constant updates.
6.3.1. SaaS (Software as a Service)
Many of these solutions are managed through a SaaS service; that is, it is a software distribution model where the software and the data it handles are hosted on the servers of an ICT company.
This type of service typically includes three components:
• HOSTING: These are cloud servers (such as AWS or Microsoft Azure) accessed via the internet from a client. It is recommended that this infrastructure have redundant firewalls to ensure maximum data security and availability. The hosting service should be adaptable to future needs for potential expansions and/or new software capabilities.
• COMMUNICATIONS: Gateways/Command Centers typically use M2M communications to communicate with the software. In most SaaS cases, the solution provider manages these communications, as this guarantees reliable communication and avoids the "ping-pong" effect between the solution provider and the communications provider, which can disrupt system performance.
• SUPPORT, MAINTENANCE, AND UPDATES: Proper maintenance and updates are essential for the platform to function correctly. Updates include improvements, new features, and bug fixes. Support is typically offered based on the number of light points, access points (Gateways), and/or electrical panels to be managed. The service level will vary depending on the client's requirements, as these may include different needs and/or modules such as:
- Inventory.
- Energy Management. - Reports.
- Invoice Upload.
Bibliography
https://www.une.org/encuentra-tu-norma/busca-tu-norma https://lucescei.com/articulo-schreder-conectividad-en-la-smart-city-a-traves-del-alumbrado-publico-copia/ https://smart-lighting.es/tecnologias-comunicacion-inalambricas-iluminacion-vial-exteriores/ https://es.wikipedia.org/wiki/Banda_ISM https://www.energy.gov/sites/prod/files/2015/09/f26/what-to-look-for-today-in-control-systems_1.pdf
https://www.talq-consortium.org/
https://www.boe.es/eli/es/rd/2008/11/14/1890 https://www.boe.es/buscar/act.php?id=BOE-A-2002-18099&tn=2&p=20200620