The TLE Series operates in VFI (voltage and frequency independent) mode and has been developed to meet the growing demand for high efficiency through a novel control algorithm with three-level inverter technology. This innovative product offers best-in-class efficiency in double-conversion mode, as well as with eBoost™ operating mode. The TLE Series was created using GE's Six Sigma design methodology to ensure the product fully meets customer requirements and expectations.
Their reliability can be further increased by installing more units in parallel thanks to GE's exclusive RPA™ (Redundant Parallel Architecture) technology. Throughout their lifecycle, GE UPS systems are supported by a qualified, world-class technical support team that provides 24/7 preventive and corrective maintenance, training, and expert consulting.
Features
• Highly efficient double conversion and eBoost operating modes (up to 96.5% and 99%, respectively).
• The high efficiency of double conversion generates significant savings in power and cooling over its lifetime, which can reach up to $2 million for a 6 MW data center.
• Clean input keeps the power grid free of interference and has the advantage of reducing the size of the circuit breaker, cables, and generator.
Front access for operation and maintenance reduces mean time to repair (MTTR).
• Integrated reverse current protection and a maintenance switch minimize installation costs and increase safety.
• Compact dimensions allow for installation in a smaller footprint.
• Reliability, redundancy, and scalability are ensured by its redundant parallel architecture for up to six UPS units.
eBoost
Energy consumption is a vital factor for IT companies, as the energy demand of their data centers constantly increases, and their goal is to reduce costs and keep the centers operational. Energy consumption can be reduced without sacrificing system reliability thanks to GE's eBoost technology.
e = efficiency up to 99%
Boost = rapid transfer to the inverter
Protection Software
: GE Data Protection software can communicate with the UPS system via RS-232, USB, or SNMP to receive status information and measurement values. In the event of a critical problem (battery life, remaining runtime, or low battery), the software initiates a controlled shutdown.
An advanced alarm management system allows applications to be launched and messages or emails to be sent regarding all active or canceled alarms.
remote monitoring and diagnostic solution (iUPSGuard)
is a UPS system monitoring and alarm notification concept compatible with all GE UPS product lines.
By accessing the latest information via the web and receiving alerts by email or SMS, users can make timely decisions in case of changes in operating conditions.
It improves diagnostic capabilities and shortens response time through detailed data collection and analysis.
include: 24/7 remote access to your UPS system data from a standard web browser
; automatic and instant alarm notifications in case of an incident, sent directly to your mobile phone or via email
; regular operational reports with proactive information on critical data
; preventive analysis information via PMAD (Preventative Maintenance & Advanced Diagnostics) functionality
; and the potential to reduce intervention times and on-site work.