The double circuit doubles the load control of the two relays in each operation, allowing two different and independent loads to be connected to each relay or managing the power of a system more efficiently, distributing a load between two lines, consequently sharing a high consumption.
In this way, the Cebek T-45 can control the connection and disconnection of 4 independent loads of up to 3 A, or use the double circuit of each relay to support only 2 loads but with double the power.
In each relay, both circuits also have switched contacts: Common, Normally Open and Normally Closed, which in turn can establish the selection of two conditions for each load, or the switching of two signals on a single input.
Both relays are independent of each other and electrically isolated from their respective control inputs, as well as from the board's power supply.
The control signal can be set with a voltage between 3 and 24 VDC and a minimum current of 5 mA. Each relay supports a maximum load per circuit of 230 V / 3 A.
The T-45 power supply can be set interchangeably from 100 to 240 VAC 50/60 Hz, making it completely versatile for use interchangeably in countries with 110 or 230 V electrical grids.
Among its main applications, it is used for the control of electrical sectors or machinery, the isolation between logic circuits with respect to power outputs, serial industrial processes, autonomous operating systems and signal selection, among others.
The T-45 measures 98 x 72 x 30 mm and is fully adaptable to DIN rail mounting using the Cebek C-7567 socket.
It has a maximum current draw of 50 mA and supports loads up to 230 V / 3 A per relay circuit.
All models include a local indicator for active connection status for each relay.