Interactive real-time control system accessible via LAN, WAN, or the Internet using any standard web browser. Connect from anywhere in the world. Only the Java Virtual Machine is required for proper display of the control website. No additional software installation is needed to access and operate the control system. Includes a software module for management, monitoring, and control via landline or mobile phone.
Integrates an RS-485 communications software module for acquiring data from other equipment or systems. Configurable communication parameters and protocol. Sends daily telemetry data files to a configured email address via GPRS. Online data download via LAN or Ethernet. Telemetry data storage capacity up to 2 MB.

CHARACTERISTICS:

- Backlit LCD display with push buttons for navigating the device's configuration and control menus.
- Installed hardware:
8 isolated digital signal inputs. 1 pre-configured input for an anemometer connection (wind speed measurement up to 250 m/s).
8 isolated relay outputs with CM, NO, and NC contacts.
1 input for an NTC temperature sensor.
1 input for a light sensor.
1 AC mains voltage input, isolated via a transformer.
- Digital inputs: 16 alarm zones, validation times, and alarm activation levels, or inputs configurable independently. User-configurable input names.
- Relay outputs: Validation times, delays, and activation levels configurable independently. User-configurable output names. Automatic or manual output configuration. Different output types: normal, impulse, delayed, etc.
- Analog inputs: Configurable maximum and minimum alarm values. Hysteresis configuration. Analog values ​​for mains frequency and voltage, lighting level, and temperature.
- Monitoring, control, alarm recognition, execution of orders, commands, and system alerts from any phone, anywhere, landline or mobile. Alarm notification, incident reporting, and control system status updates via SMS. Reception of orders and commands via tone sequences. Automatic call placement in response to a technical alarm. Activation, deactivation, and acknowledgment of alarms from a phone without needing to accept or place a call.
- Storage capacity for over 16,000 incident, event, or alarm records with date/time, origin, and generating signal information.
- Telemetry data storage capacity: 2 MB.
- Generation of alarm/event reports by date/time, which can be printed or saved to disk.
- Built-in real-time clock. In case of power failure, the date/time is maintained.
- Real-time graphical display of the global control system, where any change in status, alarm, or activation is displayed the instant it occurs. Includes a window for recent alarms.
- Integrated programmable logic controller (PLC) that allows for the execution of automatic logic functions on the device's relay outputs. Four independent weekly time schedules with 30-minute intervals.
- Web-based access validation and control using Avysecur Key technology. Each device is supplied with a unique access coordinate card.
- Connection link with integrated webcam-based video systems.
- RS-485 communication port, capable of connecting to 256 nodes.
- Application software, RS-485 communication protocol, and website updates are performed using the device's local RS-232 communication port.

More information or a quote