The RMD500-EW is designed for plug-and-play use with all the features required by EN 50155, including reverse polarity protection, EMC and surge filtering, inrush current limiting, and a 10ms hold time. It complies with all relevant railway environmental standards for conducted and radiated EMI, mechanical shock and vibration, thermal shock, temperature cycling, and fire protection.
The output power is 500W up to a base plate temperature of 95°C without power reduction, allowing operation from -40°C to, typically, +70/85°C ambient temperature and complying with the requirements of EN 50155 OT4 + ST1 and ST2. Efficiency is high, up to 95.5%, across a wide input range and even under light loads, enabling high power density in a compact, 209 x 141 x 48 mm base plate-cooled package that can be mounted in any orientation. Screw terminals are provided for convenient input and output connection.
The product is certified according to EN 62368-1 and EN 50155 (S2) with a nominal insulation rating of 3.5 kVAC. The product is extremely reliable and robust, with comprehensive protection against short circuits, output overvoltage, overcurrent, and overtemperature. Additional features include DCOK voltage-free relay contacts, remote on/off, output adjustment, and active current sharing with OR diodes for parallel operation when higher power or n+1 redundancy is required.
Other products in the series are being prepared for launch in 2022 with power ratings of 300W and 150W for broader applications in railway rolling stock and trackside equipment.
Marco Kuhn, Product Manager for Mobility at RECOM, comments: “The RMD500-EW is the first in a standard range of RECOM plug-and-play DC/DC converters for railway applications, including auxiliary traction and propulsion power supplies, braking, monitoring, safety, climate control and door control systems, data loggers, and much more. They are truly plug-and-play thanks to all their integrated functions and features.”