It is also worth noting that it meets the high energy efficiency requirements of ENERGY STAR and the EC code of conduct.

Since the 49000C series maintains the format of the EI30 series transformers, it allows for design upgrades without having to redo the PCB, increasing efficiency and maintaining the safety requirements of IEC/EN61558-2-16, IEC/EN60335, IEC/EN62368 and UL/CUL62368 standards.

Without using any additional components, the 49000C series passes the conducted and radiated EMI tests of EN55032, FCC Part 15, CLASS B. It also complies with EN61000-3-2 CLASS A, EN61000-3-3, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, and IEC61000-4-11 immunity standards

The Myrra 49000C series features a wide range of DC output voltages: 3.3Vdc, 5Vdc, 9Vdc, 12Vdc, 15Vdc, 18Vdc, and 24Vdc, all with a power output of 5W, ambient temperatures between 50°C and 60°C, operating temperatures between -25°C and 85°C, a maximum noise level of 180mVpp, and a rise time never exceeding 50ms

These Myrra 49000C series AC/DC converters are automatically protected against overcurrents. The power supply automatically resumes normal operation once the fault condition is cleared. They also withstand a continuous output short circuit without damage; the short circuit can occur before or after power-up, and in either case, the power supply will resume normal operation once the short circuit is cleared. In both protection situations, there is no excessive heat, odor, or plastic deformation, ensuring safety during the fault.